The AdVanceā„¢ male sling: does it stand the test of time?

There is minimal data published on the longevity of the transobturator retrobulbar male sling (AdVance™). We aimed to determine the efficacy, the complication rate and need for salvage SUI surgery in the medium to long term for male sling insertion.

We performed a retrospective review of all patients undergoing male sling insertion at a single centre between 2009 and 2018. Data on patient demographics, pre and post-operative International Consultation on Continence Questionnaire - Urinary Incontinence (Short Form) (ICIQ-UI(SF)) scores and 24 h pad usage were collected. Success was calculated as a combination of the cured rate (0-1 security pad use) and the improved rate (>50% reduction in pad usage). Data was also collected on complications, patient satisfaction as well as need for further SUI surgery.

A total of 91 patients underwent male sling insertion in the period specified; median follow up was 69 months. Success rates at 3 months in mild SUI, moderate SUI and severe SUI groups were 96, 86 and 80%, respectively. In the medium to long term, this drops to 65, 62 and 47%, respectively. The overall rate of artificial urinary sphincter (AUS) implantation was 15%. Common complications included groin pain (3%), infection (3%), urinary retention (10%) and de novo overactive bladder (OAB) (11%). The only factor predicting success or failure was pre-operative ICIQ-UI(SF) score.

AdVance™ male sling success rates deteriorate from 89% at 3 months to 61% at 5 years. The risk of complications is low and, for the most part, transient. Sling insertion remains a reasonable treatment option for male patients suffering with stress urinary incontinence (SUI).

Scandinavian journal of urology. 2021 Feb 01 [Epub ahead of print]

Ishtiakul G Rizvi, Pravisha Ravindra, Michelle Pipe, Ridwaan Sohawon, Thomas King, Mohammed Belal

Department of Urology, Queen Elizabeth Hospital, Birmingham, UK.