INTRODUCTION AND HYPOTHESIS: This study aimed to document intraoperative and early postoperative complications associated with the use of vaginal mesh with trocar in pelvic organ prolapse (POP) repair.
METHODS: This is a retrospective review of 120 cases of vaginal repair of POP using vaginal mesh. Of the 120 patients, 31 underwent anterior mesh repair (Light mesh 10, Avaulta 1, Perigee 1, and Prolift 19); 35 underwent posterior mesh repair (Light mesh 2, Posterior IVS 17, and Prolift 16); and 54 underwent anterior and posterior mesh (total) repair (Light mesh 8, Prolift 32, and Prolift M 14).
RESULTS: Three bladder injuries (2.5%) and one distal rectal injury (0.8%) occurred during dissection. Three of four organ injuries (75%) had previous prolapse repair. Overall four patients (3%) required transfusion. Urinary retention exceeding 5 days occurred in four patients. Three of them (60%) also underwent TVT-O. Groin pain occurred in two patients one of whom underwent TVT-O. Gluteal pain occurred in one patient. Early mesh exposure occurred in the vaginal cuff of a patient who underwent hysterectomy.
CONCLUSIONS: The vaginal mesh procedures may be done with relatively few perioperative complications. However, there is a need for more randomized controlled trials with long-term follow-up to clarify its postoperative long-term complications and morbidities.
Written by:
Demirci F, Birgul K, Demirci O, Demirci E, Akman Y, Karaalp E, Dolgun N. Are you the author?
Kadikoy Sifa Health Group, Istanbul, Turkey; Zeynep Kamil Women's Health and Maternity Hospital, Istanbul, Turkey; Baskent University, Istanbul, Turkey; Goztepe Education and Research Hospital, Medeniyet University, Dr. Erkin Street, 34170 Istanbul, Turkey.
Reference: J Obstet Gynaecol India. 2013 Oct;63(5):328-31.
doi: 10.1007/s13224-013-0396-0
PubMed Abstract
PMID: 24431669
UroToday.com Trauma & Reconstruction Section